20 Setting the Hardware
With built-in AI/AO and expansion slot AI card
CNC
AI/AO (A)
Built-in AI/AO
AI (B)
Expansion slot
AI card
*
Up to 8 points of analog input channel can be used in the connection order (A) > (B) > (C) > (D) > (E) >
(F).
- Use RIO1/RIO2/RIO3 ((C) to (F)) in the ascending order of the station numbers of RIO units.
- 9th and succeeding channels are unavailable even when they are connected.
*
Up to 4 points of analog output channel can be used in the connection order (A) > (C) > (D) > (E) > (F).
- Use RIO1/RIO2/RIO3 ((C) to (F)) in the ascending order of the station numbers of RIO units.
- 5th and succeeding channels are unavailable even when they are connected.
IB-1501268-K
Remote I/O unit with AI/AO
RIO1
RIO2
Operation panel I/O unit
RIO3
(A) Built-in AI/AO of the main body
(B) Expansion slot AI card of the main body
(C) RIO1 remote I/O unit with AI/AO
(D) RIO2 remote I/O unit with AI/AO
(E) RIO3 expansion card with AI/AO
(F) RIO3 remote I/O unit with AI/AO
AI/AO (C)
Remote I/O unit with AI/AO
Expansion card with AI/AO
AI/AO (E)
Remote I/O unit with AI/AO
438
AI/AO (D)
AI/AO (F)