J023/J024/J025 Cable - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
18 Cable

18.2.9 J023/J024/J025 Cable

Max. cable length: 20m
Application: Manual Pulse Generator cable (5V)
[MPG]
Connector : 10120-3000PE
Case : 10320-52F0-008
Manufacturer: 3M
Cable name
J023 cable
J024 cable
J025 cable
Unconnectable to control unit side
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) The cables for 1ch and 2ch are compatible with F023 or F024 cable of the conventional model.
(Note 3) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly
otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)
IB-1501268-K
MPG
MPG
4
HA1A
14
HA1B
10
+5V
1
0V
3
HA2A
13
HA2B
20
+5V
11
0V
2
HA3A
12
HA3B
19
+5V
15
0V
FG
Wire material :
UL2464 U-TKVVBS AWG22 × 6P
Manufacturer: Tachii Electric Wire
1ch
2ch
3ch
○ : Usable channel
HA1
HB1
5V1
0V1
HA2
HB2
5V2
0V2
HA3
HB3
5V3
0V3
[1ch][2ch][3ch]
Crimp terminal : R1.25-3 × 12
Manufacturer: JST
378
1ch
2ch
3ch

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents