18 Cable

18.2.5 G430 Cable

Max. cable length: 10m
Application: For connection to handy terminal
Control unit
[ENC][SIO]
Plug: 10120-3000VL
Shell: 10320-52F0-008
Manufacturer: 3M
Wire material: UL1061-2464 AWG28 x 3P
Manufacturer: Oki Electric Cable
[Control panel terminal block]
Crimp terminal: R1.25-3.5
Manufacturer: JST
Wire material: UL1061-2464 AWG24 x 8P
Manufacturer: Oki Electric Cable
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
IB-1501268-K
ENC
SIO
Cotrol panel
terminal block
ENC
HA1A
8
HA1B
18
0V
5
FG
SIO
RD(RXD)
7
SD(TXD)
17
CS(CTS)
8
RS(RTS)
18
DR(DSR)
9
ER(DTR)
19
0V
11
FG
DED1
DCOM1
DED2
DCOM2
EMG1
ECOM1
EMG2
ECOM2
SEL1
SCOM1
+24V
0V
FG terminal
Crimp terminal: V1.25-4
Manufacturer: JST
Wire material: UL1061-2464
AWG18(Green)
Manufacturer: Oki Electric Cable
HOST
HOST
16
HA
HB
17
20
0V
SD(TXD)
14
15
RD(RXD)
7
RS(RTS)
8
CS(CTS)
6
0V
1
FG
9
SW2_C11
10
SW2_C12
SW2_C21
21
22
SW2_C22
11
SW1_NC11
12
SW1_NC12
23
SW1_NC21
24
SW1_NC22
18
SW6_NO1
19
SW6_C1
25
24VDC(+)
13
24VDC(-)
FG
[HOST]
Plug: CDB-25S
Contact: CD-SC-221 ×21
Manufacturer: Hirose Electric
374