Connecting Device Via Function Expansion Unit; Connecting Device Via Encoder (Manual Pulse Generator) I/F Expansion Unit - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
7 Connection of Control Unit

7.12 Connecting Device via Function Expansion Unit

Mount the function expansion unit onto the dedicated slot of the control unit.

7.12.1 Connecting Device via Encoder (Manual Pulse Generator) I/F Expansion Unit

(1) Connecting with synchronous feed encoder
ENC
(2) Connection of manual pulse generator
When connecting one 5V
manual pulse generator
MPG
When connecting two 5V
manual pulse generators
Synchronous feed encoder
R054 cable
<Right angle>
R050 cable
5V manual pulse generator
NO.1
5V 0V A B
J026
NO.1
5V 0V A B
J027
5V manual pulse generator
(Rear view)
267
(Rear view)
NO.2
5V 0V A B
IB-1501268-K