4 General Specifications
Unit name
Item
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
General
Specifications
Working atmosphere
Altitude
Power supply voltage
Current consumption
Maximum
heating value
Mass
Outline
dimension
W×H×D
(Note 1) "Short term" means roughly within one month.
(Note 2) This value includes the maximum value of DO external load current (3.2A).
(Note 3) This value does not include DO external load current.
(Note 4) For the heating value of the I/O circuit, calculate with the number of points used.
(Note 5) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
(Note 6) The maximum value including the heating value of analog input circuit.
IB-1501268-K
FCU8-DX220/
Type
DX230/
DX231
During
operation
During
storage
Long term
Short term
3.5A (Note 2)
(W)
(kg)
(mm)
40×175×133 40×175×119 40×175×130 40×175×109 40×175×130 104×175×115
Remote I/O unit
FCU8-DX213/
DX213-1/
FCU8-DX202
FCU8-DX408 FCU8-DX409 FCU8-DX651
DX654/
DX654-1
0 to 58°C
-20 to 60°C
10 to 75% RH (with no dew condensation)
10 to 95% RH
(with no dew condensation)
(Note 1)
2
4.9m/s
or less
2
29.4m/s
or less
No corrosive gases, dust or oil mist
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
24VDC
0.3A
0.3A (Note 3)
8 (Note 4)
0.4
30
10 to 85% RH
(with no dew
condensation)
(Note 1)
0.1A
0.2A
3.7A (Note 2)
3
6 (Note 6)
8 (Note 4)
0.2
0.3
0.8