M800W/M80W Series Connection and Setup Manual
12 Connection of Remote I/O Unit

12.5 Connecting with Operation Panel I/O Unit

[Windows-based display]
Control unit
RIO3
Operation panel I/O unit
FCU8-DX830/DX834/DX837
[Non-Windows-based display]
When connecting a remote I/O unit to the 3rd RIO channel, insert it between the control unit and operation panel I/
O unit.
Control unit
RIO3
J210
Operation panel I/O unit
(*)
FCU8-DX730 occupies 11 stations, but 13 stations are occupied in total since the graphic control unit
occupies 2 stations.
Refer to "20.6.2 Connection and Station No. Setting on Remote I/O Unit" for the station No. setting.
(Note)
The maximum connectable number of remote I/O units is 32.
Operation panel I/O unit
J210
RIO3
Remote I/O unit
Max.51 stations (*)
Max. input: 1632 points
Max. output: 1632 points
FCU8-DX730
RIO3EXT
J210
Remote I/O 3ch
RIO occupied stations
1 to 4, 7 to 14, 20 to 22
J210
Remote I/O 3ch
RIO occupied stations
1 to 2, 7 to 12, 20 to 22
317
Remote I/O unit
Max.49 stations
Max. input: 1568 points
Max. output: 1568 points
Operation panel I/O unit
RIO3EXT
IB-1501268-K