Remote I/O Unit; Function Expansion Unit; Communication Expansion Unit - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
3 List of Configuration

3.10 Remote I/O Unit

Classification
DI 24V/0V common input [32 points]
DO Source output [32 points]
DI 24V/0V common input [64 points]
DO Source output [48 points]
DI 24V/0V common input
DO Source output [48 points]
AO Analog output [1 point]
AI Analog input [4 points]
AO Analog output [1 point]
DI 0V common input [16 points]
DO Source output (large capacity) [8
points]
DI 0V common input [16 points]
DO Source output (large capacity) [8
points]
Safety DI 0V common input [8 points]
Safety DO Source output (large capacity)
[4 points]
Safety DI 0V common input [8 points]
Safety DO Source output (large capacity)
[4 points]
DI 24V/0V common input [32points]
DO Source output [32 points]
Safety DI 0V common input [8 points]
(Note 1)
Safety relay output [4 points] (Note 2)
Thermistor input [12 points]
Multi-analog input [4 points] (Note 3)
(Note)
DI: Digital input signals, DO: Digital output signals, AI: Analog input signals, AO: Analog output signals

3.11 Function Expansion Unit

Classification
Encoder (manual pulse generator) I/F
expansion unit

3.12 Communication Expansion Unit

Classification
CC-Link expansion unit
PROFIBUS-DP master unit
CC-Link IE Field
Master/local unit
EtherNet/IP
Scanner/adapter unit
FL-net expansion unit
IB-1501268-K
Type
Components
Base card
FCU8-DX220
RIO 2.0 connector set
Base card
FCU8-DX230
RIO 2.0 connector set
Base card
FCU8-DX231
RIO 2.0 connector set
Base card
FCU8-DX202
RIO 2.0 connector set
Base card
FCU8-DX213
RIO 2.0 connector set
Base card
FCU8-DX213-1
RIO 2.0 connector set
Base card
FCU8-DX654
RIO 2.0 connector set
Base card
FCU8-DX654-1
RIO 2.0 connector set
Base card
FCU8-DX651
Add-on card
RIO 2.0 connector set
Base card
FCU8-DX408
RIO 2.0 connector set
Base card
FCU8-DX409
RIO 2.0 connector set
Type
Components
FCU8-EX544
Encoder I/F PCB
Type
Components
FCU8-EX561
CC-Link I/F PCB
FCU8-EX563
PROFIBUS-DP I/F PCB
Base card
FCU8-EX564
Add-on card
Base card
FCU8-EX565
Add-on card
Base card
FCU8-EX568
Add-on card
16
Remarks
DI: 32-points 24V/0V common type
Do: 32-points source type (200mA/point)
Number of occupied stations: 1
DI: 64-points 24V/0V common type
DO: 48-points source type (200mA/point)
Number of occupied stations: 2
DI: 64-points 24V/0V common type
DO: 48-points source type (200mA/point)
AO: 1 point
Number of occupied stations: 2
AI : 4 points
AO: 1 point
Number of occupied stations: 1
DI: 16-points 0V common type (3mA/point)
DO: 8-points source type (2A/point)
Number of occupied stations: 1
DI: 16-points 0V common type (9mA/point)
DO: 8-points source type (2A/point)
Number of occupied stations: 1
Safety DI: 8-points 0V common type (3mA/point)
Safety DO: 4-points source type (2A/point)
Number of occupied stations: 2
Safety DI: 8-points 0V common type (9mA/point)
Safety DO: 4-points source type (2A/point)
Number of occupied stations: 2
DI: 32-points 24V/0V common type
Do: 32-points source type (200mA/point)
Safety DI: 8-points 0V common type
Safety relay: 4-points (non-voltage contact)
Relay contact welding detection
Number of occupied stations: 3
(Note 1) Safety DI uses 16 points of terminal
because of the duplication wiring.
(Note 2) Safety relay output uses 8 points of
terminal because of the duplication wiring.
Thermistor input: 12 points
Number of occupied stations: 3
Multi-analog input: 4 points
(Note 3) Voltage input, current input,
thermocouple input and resistance temperature
detector input are selected for each CH.
Number of occupied stations: 4
Remarks
Encoder input 1ch
5V manual pulse generator input 2ch
Remarks
CC-Link 1ch
PROFIBUS-DP 1ch
CC-Link IE Field 2ch
EtherNet/IP 1ch
(Only LAN1, LAN2 cannot be used)
FL-net 1ch
(Only LAN1, LAN2 cannot be used)

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents