25 Setting the Position Detection System

25.1.2 Marked Point Alignment Method II

(1)
Preparations
Set the parameters on the Abs pos
param screen.
(2)
Turn the power OFF and ON.
(Only when "#2049 type" is specified again.)
The following are the operations on the absolute position setting screen. (Select [Mainte] - [To Abs pos])
(3)
Select an axis to set the absolute
position.
There are two methods to select an
axis.
- Select the menu [Axis select], enter
the axis name in the input area then
press [INPUT]. (For the axis name,
input the name set to the parameter
"#1022 axname2" (2nd axis name).)
- Press the menu [Prev axis] and [Next
axis] to switch the axis.
(4)
Select "HANDLE" or "JOG" for the
machine operation switch.
(5)
Confirm that the cursor is placed on
"Absolute posn set", input "1" in the
input area and press the [INPUT] key.
(6)
Move the cursor to "Zero-P" with
the [ ↑ ] and [ ↓ ] keys.
Enter the value in the input area of
"Zero-P" and press the [INPUT] key.
#2049 type (absolute position detection method): 4
#2059 zerbas (zero return parameter): 0
The parameters other than "#2049 type" can also be set in Absolute
position setting screen.
The input value is registered in the "Absolute posn set" area.
State: [Origin set]
The input value is registered in the "Zero-P" area.
487
(marked point alignment method II)
Selected axis
IB-1501268-K