16 Connection of Machine Operation Panel

16.2 Connecting with Power Supply

Connect 24VDC power supply (general-purpose stabilized power supply) to the main panel of the machine operation
panel.
[FCU8-KB921/KB922/KB923/KB924/KB925/KB926]
<Related items>
Cable drawing: "Cable: J070/J071 Cable"
Connector pin assignment: "General Specifications: Machine Operation Panel: Main Panel A,B" (DCIN connector)
When sharing the 24VDC power supply with the control unit, connect a 24VDC relay cable.
[FCU8-KB921/KB922/KB923/KB924/KB925/KB926]
<Related items>
Cable drawing: "Cable: G071 Cable"
Connector pin assignment: "General Specifications: Machine Operation Panel: Main Panel A,B" (DCOUT
connector)
DCIN
DCOUT
G071
357
Stabilized power supply
24VDC(+)
0V
FG