7 Connection of Control Unit

7.10 Connecting with Skip Signal (Sensor)

Connect the skip signals to SKIP connector of the control unit.
Skip signals are used for processing high-speed signals. Always shield the cable.
Control unit
SKIP
(Note)
Connecting the skip signal cable to a wrong connector causes a damage on the control unit when turning ON
the skip signal power supply. Confirm the wiring before turning the power ON.
(1) Connection of skip signal cable
<0V connection at COM terminal>
Control unit
SI1
SI2
SI3
SI4
SI5
SI6
SI7
SI8
0V connection at COM terminal
COM
COM
SK0
J100
SK1
SK2
SK3
COM
COM
SK4
SK5
SK6
SK7
SKIP
J100
2.35kΩ
2
12
3
13
7
17
8
18
COM
1,5,11,15
FG
Stabilized
power supply
24VDC(+)
0V
FG
263