Mitsubishi Electric M800W Series Connection And Set Up Manual page 399

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
16 Connection of Machine Operation Panel
<Wiring of rotary switch (SUBP)>
(Note 1) Use the special lead wire with a connector for wiring of rotary switch.
(Note 2) A09 to 12 and B09 to 11 of SUBP are spares, so they do not need wiring.
(Note 3) Select a rotary switch which guarantees 5V/1mA.
(Note 4) Length of cables must be 0.5m or shorter.
(Note 5) The numbers in the above diagram do not indicate the actual device numbers.
IB-1501268-K
Main panel A/B (FCU8-KB92x)
+5V
R
A01
X60
R
B03
X61
R
B01
X62
R
A03
X63
R
A02
X64
R
A04
X65
B02
+5V
R
A05
X66
R
B07
X67
R
B05
X68
R
A07
X69
R
A06
X6A
R
A08
X6B
B06
+5V
R
A09
X6C
R
B11
X6D
R
B09
X6E
R
A11
X6F
R
A10
X70
R
A12
X71
B10
Lead wire with a connector: ACX011-705 (7 terminals, 0.5m) Fuji Electric
Sub panel A (FCU8-KB931/KB941)
[SUBP]
Rotary Switch
A
(For cutting
feedrate override)
F
21 position
B
Real gray code
E
C
G
D
Rotary Switch
A
(For rapid
traverse override)
F
B
Real gray code
E
C
G
D
A
F
Rotary Switch
B
E
C
G
D
360
8 position
(Spare)

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents