M800W/M80W Series Connection and Setup Manual
4 General Specifications
[LED]
(1)
(2)
(3)
(4)
Name
(1) RUN (Green)
(2) RDY (Yellow)
(Module status)
(3) STA (Green)
(4) ERR (Red)
(Communication status)
(Note 1) All LED (RUN, RDY, STA and ERR) are lit during the reset of PROFIBUS-DP module.
(Note 2) The status of PROFIBUS-DP module is displayed by the combination of RUN/RDY.
(Note 3) The status of PROFIBUS-DP communication is displayed by the combination of STA/ERR.
IB-1501268-K
Color
Status
Green
Lit
Lit when PROFIBUS-DP module is normally operated
Green/
Flashing
Boot standby
yellow
Yellow
Lit
Boot error
-
Lit
No power supply, module failure
Configuration successful, communication
Green
Lit regularly
unestablished
Green
Lit randomly
Configuration failure, stuck error
Green
Lit
Communicating with slave(s)
Red
Flashing
Communication is interrupted with at least one slave
Red
Lit
Communication is interrupted with all the slaves
172
Details