25 Setting the Position Detection System
(7)
Start JOG operation.
The axis moves toward the machine
end stopper at the pushing speed
(#2055 pushf).
(8)
After the axis pushes against the
machine end stopper and the current
reaches its limit continually during
given time period, the axis returns
toward the approach point at the
pushing speed.
(9)
After the axis arrives at the approach
point, the axis moves toward the
machine end stopper at the pushing
speed.
(10)
When the parameter "#2059 zerbas"
is set to "0", the axis pushes against
the machine end stopper and stops
when the current reaches its limit.
(11)
When the parameter "#2059 zerbas"
is set to "1", the axis pushes against
the machine end stopper, and the
current reaches its limit, the axis
reverses and moves at the pushing
speed (#2055 pushf). Then the axis
stops at the first grid point.
Move the cursor to "Zero-P" with the [
↑ ] and [ ↓ ] keys. Input the distance
from basic machine coordinate
system zero point to the grid point
immediately preceding the basic
position then press [INPUT].
The zero point initial setting is now complete. After initializing all axes, turn the power OFF and ON.
IB-1501268-K
State: [Stopper1]
State: [Zero-P. Rel.]
State: [Stopper2]
State: [Complete]
Machine end: 0.000
Machine position: Current machine position
State: [Complete]
Machine end: Distance from the machine end stopper to position
immediately preceding the grid point
Machine position: Current machine position