7 Connection of Control Unit

7.13.3 Connecting I/O Device via CC-Link IE Field

The expansion unit FCU8-EX564 functions as master station or slave (local) station of CC-Link IE Field. Connect the
CC-Link IE Field-compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable).
For details, refer to "M800/M80 Series CC-Link IE Field (Master/local) Specifications manual".
CC-Link IE Field unit
(FCU8-EX564)
Connector for
CC-Link IE Field
communication
[Noise countermeasures of ethernet cable]
When the CC-Link IE Field expansion unit is being used, expose the cable by removing a part of the cable sheath
and make sure to use the shield clamp for the exogenous noise countermeasure.
When you cannot use the shield clamp, make sure to install a ferrite core as a substitute to ethernet cable (near the
expansion unit).
<Related item>
Shield clamp fitting: "EMC Installation Guidelines: EMC Countermeasure Parts: Shield Clamp Fitting"
Ferrite core: "EMC Installation Guidelines: EMC Countermeasure Parts: Ferrite Core"
CC-Link IE Field-compatible equipment
Ethernet cable
(category 5e or above and
twisted pair cable with shield)
Ethernet cable
Shield
273
Switching hub
Slave station
Slave station
Slave station
(* Prepared by MTB)