13. Program Support Functions
13.14 Start Point Designation Synchronizing (Type 1); G115
Function and purpose
The part system can wait for the other part system to reach the start point before starting itself.
The synchronization point can be set in the middle of a block.
Command format
!nL1
G115
!nL1
G115
X_ Z_ C_
Detailed description
(1)
Designate the start point using the workpiece coordinates of the other part system.
(2)
The start point check is executed only for the axis designated by G115.
(Example) !L2 G115 X100.;
Once the other part system reaches X100., the own part system will start. The other axes are
not checked.
(3) The other part system starts first when synchronizing is executed.
(4) The own part system waits for the other part system to move and reach the designated start
point, and then starts.
13.14 Start Point Designation Synchronizing (Type 1)
X_ Z_ C_ ;
Synchronizing command
G command
Start point (Command axis and workpiece coordinate values for checking
synchronization of other part system.)
Own part system
Other part system
Own part system
Other part system
271
!G115
Synchronized
operation
!
!G115
Synchronized
operation
!
Designated start point
Designated start point