4 General Specifications
(6) RIO3EXT (Remote I/O 2.0 communication)
(7) RIO3 (Remote I/O 2.0 communication)
X
B
A
1 2 3
A
1
I/O
TXRXD
2
NC
3
FG
<Cable side connector type>
Connector : 1-1318119-3
Contact : 1318107-1 x6
Manufacturer: TE Connectivity
Refer to the following chart for the maximum number of connecting stations and I/O points to the connector
RIO3.
Operation panel I/O unit type
FCU8-DX830/DX834/DX837
Refer to the following chart for the maximum number of connecting stations and I/O points to the connector
RIO3EXT.
Operation panel I/O unit type
FCU8-DX730 (*)
(*)
FCU8-DX730 occupies 11 stations, but 13 stations are occupied in total since the graphic control unit
occupies 2 stations.
(Note 1) Refer to the section "General Specifications: Remote I/O Unit" for the number of occupying stations and I/
O points of remote I/O units.
(8) EMG (Emergency stop connection)
3
2
1
1
FG
2
I
EMG IN
3
O
+24V
- Be sure to connect EMG terminal cable (G123) to the connector when not used.
<Cable side connector type>
Connector : 50-57-9403
Contact : 0016020103
Manufacturer: MOLEX
B
1
I/O
TXRXD*
2
0V
3
NC
Max. number of stations
(RIO3 connection)
49 stations
(5th, 6th, 15th to 19th, and 23rd to
64th stations can be used)
Max. number of stations
(RIO3EXT connection)
51 stations
(3rd to 6th, 15th to 19th, and 23rd
to 64th stations can be used)
111
Max. number of I/O points
(RIO3 connection)
1568 points/ 1568 points
Max. number of I/O points
(RIO3EXT connection)
1632 points/ 1632 points