20 Setting the Hardware
Without built-in AI/AO
CNC
*
Up to 8 points of analog input channel can be used in the connection order (A) > (B) > (C) > (D).
- Use RIO1/RIO2/RIO3 ((B) to (D)) in the ascending order of the station numbers of RIO units.
- 9th and succeeding channels are unavailable even when they are connected.
*
Up to 4 points of analog output channel can be used in the connection order (A) > (B) > (C) > (D).
- Use RIO1/RIO2/RIO3 ((B) to (D)) in the ascending order of the station numbers of RIO units.
- 5th and succeeding channels are unavailable even when they are connected.
Remote I/O unit with AI/AO
RIO1
RIO2
Operation panel I/O unit
RIO3
(A) RIO1 remote I/O unit with AI/AO
(B) RIO2 remote I/O unit with AI/AO
(C) RIO3 expansion card with AI/AO
(D) RIO3 remote I/O unit with AI/AO
AI/AO (A)
Remote I/O unit with AI/AO
Expansion card with AI/AO
AI/AO (C)
Remote I/O unit with AI/AO
439
AI/AO (B)
AI/AO (D)
IB-1501268-K