M800W/M80W Series Connection and Setup Manual
4 General Specifications
Input conditions
The input signals must be used within the following condition ranges.
1
2
3
4
5
6
7
8
9
(*1)
Connection to 0V common input
(E)
+24V
(I)
(13) CJ71 (Graphic control unit I/F)
B
A
1 2 3 4
A1
I/O
TXRXD
A2
-
+5V
A3
-
-
A4
-
FG
<Cable side connector type>
Connector : 2-1318119-4
Contact : 1318107-1
Manufacturer: TE Connectivity
(14) FG (FG terminal)
Input voltage at external contact ON
Input current at external contact ON
Input voltage at external contact OFF
Input current at external contact OFF
Input resistance
Tolerable chattering time (T1)
Input signal holding time (T2)
input circuit operation delay time (T3 and T4)
Machine side contact capacity
Note that "40 ms or more" is a guide of the "Input signal holding time".
The input signal is recognized only when its "ON" state is held longer than the ladder
processing cycle time.
T2
T1
GND
T3
(E) : External signal, (I):Internal signal
B1
I/O
TXRXD*
B2
-
+3.3V
B3
-
0V
B4
-
0V
18V or more, 25.2V or less
3mA or more
0.7mA or less
40ms or more (*1)
30V or more, 16mA or more
T1
T4
115
0V common
3.8V or less
5kΩ
3ms
3 to 16ms
IB-1501268-K