Zone types

The following zone types are available.
1. Alarm
Generates no alarm when the area is unset.
Generates an alarm when the area is set.
Example: Internal door, PIR (motion detector).
2. Entry/Exit 1
Generates no alarm when the area is unset.
When the area is set, the exit timer starts and activating the zone generates no
alarm. If the zone is activated when the exit time has expired, the entry timer
starts. Only when the entry time has expired, an alarm is generated.
Example: Front door.
You need to program the entry/exit time. See "5 Area menu" on page 113 for
more information.
3. Access
Generates no alarm when the area is unset.
Generates an alarm when the area is set, and the no exit timer or entry timer is
not running.
Example: PIR at entrance with a door contact on the entry door.
You need to program the entry/exit time. See "5 Area menu" on page 113 for
more information.
4. Fire
Generates a fire alarm regardless of the status of the area.
Fire alarm causes pulsing siren sound. This alarm has higher priority than an
intrusion alarm.
Example: Smoke detector.
5. Panic
Generates a panic alarm regardless of the status of the area.
Example: panic button.
See also "8.8.1 Panic mode" on page 158.
6. 24H
Generates an intrusion alarm regardless of the status of the area.
7. Tamper
Generates a tamper alarm regardless of the status of the area.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
233