Interlogix Advisor Advanced ATS 000A Series Installation And Programming Manual page 111

Table of Contents

Advertisement

4.1.n.6.22 Log
22 Log
>No<
The Log option determines whether the zone event is recorded in the system log.
4.1.n.6.23 CS report
23 CS report
>No<
The CS report option determines whether the zone event is reported to the
central station.
4.1.n.6.24 Delay timer
24 Delay timer
>No<
A delay timer is activated for this zone if the Delay timer option is set to Yes. The
delay timer is set in "8.1.4.4 Input delay" (see page 142).
4.1.n.6.25 ACK on keypad
25 ACK on keypad
>Keypad 1<
Acknowledge options are available for keyswitch zone type. They allow you to
define a keypad where the particular user is logged in automatically. This causes
that an alarm and fault information is displayed instantly on the selected keypad.
The ACK session opens for 2 minutes. During this time you can acknowledge the
alarm on the programmed keypad.
"4.1.n.6.26 ACK by user" below must be also set for the acknowledgement
Note:
functionality to work.
4.1.n.6.26 ACK by user
26 ACK by user
>User 3<
The option defines the user that is logged in automatically when the selected
zone causes an alarm.
"4.1.n.6.25 ACK on keypad" above must be also set for the
Note:
acknowledgement functionality to work.
See "4.1.n.6.25 ACK on keypad" above for more details.
See also "2.2.1.n.3.15 ACK on keypad" on page 73.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
101

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents