Set keypad output 7 to activate continuous keypad buzzer sound, or output 8
to activate intermittent sound.
Siren outputs
The siren outputs on the Advisor Advanced control panel have addresses
starting from 1 (see Table 3 below).
On expanders with siren speaker outputs, output 16 is the siren output.
To enable the siren output, the programmed output must have the required
condition filter assigned (defined by an alarm event or a siren event, depending
on the preference settings). See "Filters, outputs, and triggers" on page 116 for
more details.
Default output assignments
The default output assignments are shown in Table 3 below.
Table 3: Default output assignments
Output
Name
Type
Panel 1
S1
High current output
Panel 2
S2
High current output
Panel 3
S3
Low current output
Panel 4
S4
Low current output
Panel 5
S5
Low current output
Keypad 7
Virtual
Keypad 8
Virtual
Note:
Output assignments may require adjustment to comply with EN 50131.

Zone and output addressing

Table 4 below shows the zone and output addressing in the Advisor Advanced
system.
Table 4: Zone and output numbering
Device
Panel
Input expander
(ATS608)
Expander 1
Expander 2
Expander 3
Expander 4
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Zones
Outputs
1–8
1–8
9–16
N/A
17–48
17–48
49–80
49–80
81–112
81–112
113–144
113–144
Default output function
EN 50131 Grade 3: Internal siren output S1
VdS: External siren output S1
EN 50131 Grade 3: External siren output S1
VdS: External siren output S2
A1 burglar alarm
A1 ready to set
A1 set
Continuous buzzer sound
Intermittent buzzer sound
Device
2X ATS1810 relay
cards
Output expander
(ATS62x)
Keypad 1
Keypad 2
Keypad 3
Keypad 4
Zones
Outputs
17–24 [1]
9–16
1001–1008
1009–1016
1017–1024
1025–1032
23

Advertisement