Interlogix Advisor Advanced ATS 000A Series Installation And Programming Manual page 167

Table of Contents

Advertisement

8.7.7.5 EE inhibit
5 EE inhibit
>Entry/Exit<
The EE inhibit option defines the functionality of the access zone in the area (if
available) when an entry/exit (EE) zone is inhibited at the end of the AB time
(auto-inhibit function). The following values are allowed:
Entry/Exit: an access zone acts as an entry/exit zone, if the entry/exit zone is
inhibited.
Access: an access zone does not change its functionality and causes an
alarm when activated while no EE timer is running.
8.7.7.6 TA confirm
6 TA confirm
>No<
If the TA confirm option is set to Yes, tamper alarm (TA) can report a B-alarm for
burglary alarm (BA), and vice versa.
8.7.7.7 Sirens
1 Area 1
>A-ALARM<
The Sirens menu allows you to select per area when the siren is activated: on A-
alarm or on B-alarm.
Option B-alarm is valid only if AB mode is enabled. See "8.7.7.1 AB mode"
Note:
on page 155.
8.7.7.8 Call CS message
8 Call CS msg
>No<
If the Call central station message option is set to Yes, in case of alarm the
keypad displays a message with advice for the user to call the central station
when a report has been sent.
8.7.7.9 Reporting delayed
9 Rep. delayed
>Yes<
Enable a 30-second delay before alarm reporting required by ACPO regulations.
8.7.8 Easy unset
8 Easy unset
>Yes<
If enabled, you can unset premises entering a PIN or badging a valid card
without pressing any other keys.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
157

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents