8.8.4 Siren retrigger
4 Siren retrig.
>No<
If there are multiple alarms, and the Siren retrigger option is set to Yes, the
external siren activates every time an alarm occurs. Otherwise, the external siren
activates only after the first alarm.
8.8.5 Short sup. and IP polling
5 Spvn&IP poll
>Always<
The option defines when wireless devices short supervision and OH IP polling
events are indicated. The following options are available:
Always: Short supervision and IP polling events are always shown.
On set: Short supervision and IP polling events are displayed only when
system set attempt.
See also "2.2.2.n.4.4.1 Short superv." on page 77 and "9.1.n.8.3.2 Heartbeat
time" on page 169.
8.8.6 Card learn-in
6 Card learn-in
>Keypad 1<
Choose a keypad for user card learning. See also "3.1.n.3 User card" on page
85.
8.8.7 Test inputs
7 Test inputs
>All<
The Test inputs option defines what inputs should be accessible when
performing input tests as described in "1.2.1 Input tests" on page 46. The
following options are available:
All: All inputs are visible.
If used: Only the inputs assigned to the existing zones are visible.
8.8.8 Buzzer mode
8 Buzzer mode
>Continuous<
The Buzzer mode menu defines how the keypad buzzer works during the exit
time. The following options are available:
Continuous: The keypad buzzer emits a continuous sound that switches to an
intermittent during an entry/exit or access zone activity.
Intermittent: The keypad buzzer emits a continuous sound and switches to an
intermittent 10 seconds before the exit time expires.