9.1.n.3 Protocol
3 Protocol
>(X)SIA<
Choose the appropriate communication protocol.
Depending on the settings in "9.1.n.2 Transm path" on page 163, the following
protocols can be available:
SIA
(X)SIA
VOICE
CID
OH+SIA
OH+XSIA
OH+CID
SMS TEXT
SMS+CID
SMS+SIA
SMS+XSIA
VOICE+SMS
SMS+MMS
OHPHOTO+CID
OHPHOTO+SIA
OHPHOTO+XSIA
PHOTO+XSIA
9.1.n.5 Accounts
1>Area 1
None
Account numbers identify alarm systems reporting to central stations. Account
numbers are 4 to 6 digits long (depending on the type of protocol). If set to None,
the reporting for the selected area is disabled.
Note:
When using voice reporting, account codes are used to identify if alarms
for an area should be reported. The account code is not transmitted.
In case a few areas have the same account numbers, and "9.1.n.9 OP/CL report"
option on page 167 is set to Yes, a special operation takes place for SIA/XSIA
reporting of opening/closing depending on the area modifier setting (see
"9.1.n.8.1 XSIA", page 165).
Area modifier off: Closing is reported when all areas with the same account
number have been set. The area that was set last is reported. The first to
disarm sends the opening signal for the area to be opened.
Area modifier on: Opening and closing signals are reported separately. The
Area Modifier is used to identify the correct area.
Note:
System events, as well as Area 1 events, are always reported using
Account 1.