4.1.n.6.27 Sensor type
27 Sensor type
>Low temp.<
The events reported by a technical zone depend on the type of the sensor
connected. The Sensor type option specifies what is the sensor and what events
it should report. The following sensor types are available:
Low temperature detector
High temperature detector
Gas detector
Water detector
Fire alarm
Generic
Table 26 below lists events that may be reported for each sensor type.
Table 26: Sensor types and reported events
Sensor Type
Code
Low temp.
SIA
CID
Gas
SIA
CID
High temp.
SIA
CID
Water
SIA
CID
Fire
SIA
CID
Generic
SIA
CID
See also "Reporting codes used in Advisor Advanced" on page 223.
4.1.n.6.28 Virtual zone
28 Virtual zone
Not set
The menu allows mapping the selected zone to an existing output.
If an output is not set, the zone state follows the state of the physical input
assigned.
If an output is selected, the zone becomes a virtual zone that is active, when the
selected output is active. In this case the physical input has no effect on the
zone.
102
Alarm
Alarm
restore
ZA
ZR
E152
R152
GA
GR
E151
R151
KA
KR
E158
R158
WA
WR
E154
R154
FA
FR
E110
R110
UA
UR
E150
R150
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Bypass
Unby-
pass
ZB
ZU
E570
R570
GB
GU
E570
R570
KB
KU
E570
R570
WB
WU
E570
R570
FB
FU
E570
R570
UB
UU
E570
R570
Super-
Super-
vision
vision
long
restore
ZS
ZJ
E381
R381
GS
GJ
E381
R381
KS
KJ
E381
R381
WS
WJ
E381
R381
FT
FJ
E373
R373
ZS
ZJ
E381
R381

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents