See also "Outputs" on page 120.
4.1.n.6.29 Held open
29 Held open
>No<
The menu defines if this zone raises a "zone open too long" alarm while held
open longer than for a defined period.
The held open period is defined in "8.1.4.6 Held open time" on page 142.
If the option is active, the option "4.1.n.6.4 Double knock" on page 97 is
Note:
not available.
4.1.n.6.30 EE set check
30 EE set check
>No<
If set to yes, entry/exit or access zone must be in a normal state when setting the
area. Otherwise, the user is not allowed to set premises until the problem is
solved.
The option is only available for entry/exit and access type zones.
4.1.n.6.31 Alarm in PS1
31 Alarm in PS1
>No<
If the option is set to yes, entry/exit zone becomes an alarm zone during part
set 1.
Notes
The option is only available for entry/exit type zones. See "Zone types" on
page 233
The zone must be included into part set 1. See "4.1.n.6.2 Excl. in PS1" on
page 97.
Zone functionality does not change if the same zone belongs to an area in full
set state.
4.1.n.6.32 Alarm in PS2
The same as "4.1.n.6.31 Alarm in PS1" above, but for part set 2.
4.1.n.6.33 Report as
33 Report as
>Panic (PA)<
Defines how panic alarm is reported to central stations.
Report as panic: PA event is reported.
Report as duress: HA event is reported.
See "Reporting codes used in Advisor Advanced" on page 223 for details.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
103