Group
Event
FTCTAMPER
CHIME
PSCHIME
USCHIME
ZNACTIVE
ZNINHIBIT
ZNISOLATE
ZNFAULT
ZNAM
ZNTAMPER
KEYPADTAMPER
KEYPADFAULT
EXPANDERTAMPER
EXPANDERFAULT
DURESS
FSDURESS
PSDURESS
USDURESS
FTCDURESS
CODETAMPER
ENTRY
EXIT
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
#
Event description
38
Tamper and FTC
39
Chime
40
Chime during part
set
41
Chime during unset Active for 2 sec when zone with
42
Zone active
43
Zone inhibit
44
Zone isolate
45
Zone fault
46
Zone masking
47
Zone tamper
48
Keypad tamper
49
Keypad fault
50
Expander tamper
51
Expander fault
52
Duress
53
Duress during full
set
54
Duress during part
set
55
Duress during
unset
56
Duress and FTC
57
Code tamper
58
Area entry
59
Area exit
Notes
A tamper alarm active while FTC
present
Active for 2 sec when zone with
chime option is active
Active for 2 sec when zone with
chime option is active during
part set
chime option is active during
unset
At least one zone in the area is
in active state
At least one zone in the area is
inhibited
At least one zone in the area is
isolated
At least one zone in the area is
in fault state
At least one zone in the area is
in anti-mask alarm state
At least one zone in the area is
in tamper state
A keypad assigned to the area is
in tamper state
A keypad assigned to the area is
in fault state
An expander assigned to the
area is in tamper state
An expander assigned to the
area is in fault state
Duress code used in the area
Duress code used while area full
set
Duress code used while area
part set
Duress code used while area
unset
Duress code used while FTC
present
Active when a
keypad
assigned
to the area is locked for 2
minutes due to 3 wrong PIN
entries
Area entry time is active
Area exit time is active