Interlogix Advisor Advanced ATS 000A Series Installation And Programming Manual page 63

Table of Contents

Advertisement

1.2.5.2.6 Siren tamper
6 Siren tamper
>No<
If the Siren tamper option is set to Yes, the tamper alarms from sirens assigned
to this area also have to be tested.
1.2.5.2.7 Frequency
7 Frequency
>Never<
The Frequency setting defines, how often the user is requested to perform the
user walk test prior to setting an area. The following options are available:
Table 16: Walk test frequency
Value
Description
Never
User walk test is not requested
Every set
User is asked to perform the walk test prior to each set
1st set of day
User is asked to perform the walk test prior to the first set each day
1st set of week
User is asked to perform the walk test prior to the first set each week
1st set of month
User is asked to perform the walk test prior to the first set each month
Note:
For walk test purposes Advisor Advanced stores information on any zone
activation for 4 hours. Therefore if the zone was activated during the last 4 hours
before walk test, it is not included into the list of zones required to test. If each
walk test zone was activated during this time, the walk test is not requested.
1.2.5.2.8 Need to set
8 Need to set
>Off<
If Need to set option is set to On, the requested user walk test is obligatory. The
area cannot be set until the walk test is passed.
1.2.5.2.9 Reduced walk
9 Reduced walk
>4h<
Reduced walk test period is a time period before reduced walk test start, in which
particular zone activation excludes this zone from the list of zones being tested.
The following options are available:
4h: Reduced walk test only includes zones that were not active during last
4 hours.
Set2set: Reduced walk test only includes zones that were not active since the
last set.
See "1.2.5.1 Walk test start" on page 51 for more details on reduced walk test.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
53

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents