Exceptions

7.4 Exceptions
0>Add exception
1 Exception 1
Exceptions represent particular time periods when everyday actions are
expanded or substituted by other actions. An example of exception is a holiday,
when the premises must stay set for 24 hour.

Exception validity note

There can be up to 64 exceptions available in the system. However, if there are a
few exceptions valid in the present day, only one exception (with the highest
number of all valid exceptions) is applied.

Exception settings

7.4.0 Add exception
Access the menu to add an exception. If the exception is created successfully,
the following message appears:
INFO
Exception added
The new exception is given the default name "Exception N" and placed on the
end of the exception list. You can now start editing the exception details for the
new exception.
7.4.n Select exception
1>Name
Exception 1
Select an exception to program.
7.4.n.1 Exception name
1 Name
>Exception 1
<
Every exception can be programmed with a name to identify it.
Use the Exception name screen to enter or edit the exception name. Exception
name can contain up to 16 characters.
7.4.n.2 Start date
2 Start [dd.mm]
>01.01<
Enter the first day of the exception in DD.MM format.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
133