Other options

8.8 PA and other
1>Panic mode
Silent
The menu allows you to configure panic alarm mode, chime, and buzzer options,
etc.
8.8.1 Panic mode
1 Panic mode
>Silent<
Panic mode can be one of the following.
Table 36: Panic modes
Option
Silent
Audible
Audible alarm if line fault
8.8.2 Chime
1>Chime in PS
No
The Chime menu allows you to set up chime options.
8.8.2.1 Chime in part set
1 Chime in PS
>No<
The Chime in part set option defines whether the chime option is active when the
area is in the part set mode.
8.8.2.2 Latched chime
2 Latched chime
>Yes<
If the Latched chime option is set to Yes, disabling the chime only affects the
chime functionality until the next time the area is unset. Otherwise it should be
enabled manually.
8.8.3 System tamper areas
3 SysTamp areas
>1.......<
The System tamper areas option allows assigning system tampers and faults to
the specified areas. At least one area must be selected.
158
Description
The panic alarm is silent (no siren activation)
The panic alarm is standard (with siren activation)
The panic alarm is audible only if a Line Fault (LF) or a Failed To
Communicate (FTC) fault is present