9.1.n.8.3 OH 2000
1>Version
OH V1.9.3
The OH 2000 menu allows you to set up a few OH 2000 protocol options that are
listed below.
9.1.n.8.3.1 Version
1 Version
>OH V1.9.3<
The following versions of the OH 2000 protocol can be used for Osborne-
Hoffman receiver communication:
OH V1.9.3
OH V2
OH V3
See an appropriate receiver's manual for more details.
9.1.n.8.3.2 Heartbeat time
2 Heartbeat time
>00:01'00<
The heartbeat time defines how often the panel sends a presence message
(heartbeat) to the central station. The range for this value is from every second
(00:00'01) to every day (23:59'59). The maximum value 23:59'59 means the
heartbeat functionality is disabled.
9.1.n.8.3.3 Receiver nbr
3 Receiver nbr
>0001<
A receiver identifier used in central stations with multiple receivers. The allowed
value is a hexadecimal number from 0001 to FFFF.
9.1.n.8.3.4 Line nbr
4 Line nbr
>0001<
A line identifier used in central stations with multiple receiving lines. The allowed
value is a hexadecimal number from 0001 to FFFF.
9.1.n.8.3.5 Freq. HB time
5 Freq. HB time
>00:01'00<
If the primary CS communication fails, the backup CS heartbeat time is switched
from normal to frequent.
See also "9.1.n.8.3.2 Heartbeat time" above.