During E/E: Buzzer remains silent during entry and exit time.
2.2.1.n.3.9 Quick set
9 Quick set
>Off<
The Quick set option allows setting areas without providing user PIN or card. If
this functionality is on, the premises are set after pressing On without user
authorization.
The following options are available:
Off: Quick set is disabled
Without list: All areas assigned to the keypad are set after pressing On
With list: After On is pressed, the system prompts to choose areas from those
assigned to the keypad.
This option affects part setting as well.
2.2.1.n.3.10 Function keys
1>F1 key
2 F2 key
Function keys menu allows you to assign a user programmable function to any of
available function keys. See "User programmable functions" on page 193 for
more details.
Function keys availability depends on the keypad type. See also "2.2.1.n.1
Keypad type" on page 68.
2.2.1.n.3.11 Area ind.LED1
11 Area ind.LED1
>........<
Area ind.LED1 allows you to assign areas to the programmable LED 1 of the
keypad. The indicator is green when all areas assigned are ready to set. It turns
red when any area assigned is set or part set. The red indicator is flashing when
there is an alarm in an area assigned to it.
Note:
This functionality is different when only one area is assigned to both
indicators. In this case the combination of two indicators shows another two
states of this area:
LED 1 is red, LED 2 is off: The area is in part set 1 state.
LED 1 is off, LED 2 is red: The area is in part set 2 state.
This indication requires the selected keypad to be assigned only to this particular
area both for view and control. See "2.2.1.n.3.3 View areas" on page 69 and
"2.2.1.n.3.4 Control areas" on page 70.