9.3.n.7.7 Line fault
7 Line fault
>No<
If the Line fault option is set to Yes, the line is tested for line faults. If a line fault is
present a fault is generated in the system.
9.3.n.7.8 Disconn.time
8 Disconn.time
>02:00<
The connection is automatically closed when no data is sent during the
Disconnection time. The connection is reinitialised when necessary.
Minimum disconnection time is 5 min. If the time is set to 23:59 or more, it
changes to Infinity. In this case the connection never closes.
Caution:
If the system should receive requests from PC incoming via GPRS, the
disconnection time must be set to infinity for the connection to stay always open.
9.3.n.7.9 Max Pics 24h
See "9.3.n.10 Max Pics 24h" on page 178.
9.3.n.8 Ring setup
1>Ring count
2 Omit 1st call
The menu contains ringing configuration options.
9.3.n.8.1 Ring count
See "9.3.n.7 Ring count" on page 175.
9.3.n.8.2 Omit 1st call
2 Omit 1st call
>No<
Use this option when sharing a telephone line with other equipment (for example,
a fax or an answering machine) that automatically answers incoming rings.
If set to Yes, the panel hangs up after a number of incoming rings programmed in
"9.3.n.8.1 Ring count" above, and answers immediately to the second incoming
call received within 30 seconds after the first one.
If set to No, the panel answers after a number of incoming rings programmed in
"9.3.n.8.1 Ring count".
9.3.n.9 Encryption
See "9.3.n.8 Encryption" on page 175.
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
185