Shock Sensor Options; Wireless Sensor Options - Interlogix Advisor Advanced ATS 000A Series Installation And Programming Manual

Table of Contents

Advertisement

Notes
This option is only available for panic type zones. See "Zone types" on page
233.
The option is only available when Panic mode is set to Silent. Otherwise
panic alarm is always reported as PA event. See "8.8.1 Panic mode" on page
158.

Shock sensor options

4.1.n.7 Gross and Pulse options
7>Grs&Pls opts
>>>
The Gross and Pulse options are valid if the "4.1.n.6.12 Shock sensor"
functionality (see page 99) for this zone is set to Yes.
4.1.n.7.1 Pulse count
1>Pulse count
0
Set the number of pulses within a time window that will activate the zone.
The following values are applicable:
1 to 9: number of pulses within 30 seconds that activates the zone. Only 1
count per second is taken into account.
0: the counter functionality is disabled.
4.1.n.7.2 Gross level
2>Gross level
0
Use the Gross level option to set the level for a single pulse that activates the
zone. The following values are applicable:
1 to 9: Gross attack level where 1 means high sensitivity, and 9 means low
sensitivity
0: Gross level is disabled
Gross level can be checked in menu "1.2.2 ShockSens test" (see page 49).

Wireless sensor options

4.1.n.7 RF details
1>Sensor ID
10EBA9E
The RF details menu allows you to program a wireless device manually, or
remove it from the wireless expander.