4.1.n.6.10 Engineer walk test
10 Eng walk test
>No<
If the Engineer walk test option is set to Yes, the zone is included in the Engineer
walk test. See "1.2.5 Walk test" on page 50 for more details.
4.1.n.6.11 User walk test
11>User walk
>Yes<
If the User walk test option is set to Yes, the zone is included in the User walk
test. See "1.2.5 Walk test" on page 50 for more details.
4.1.n.6.12 Shock sensor
12 Shock sensor
>No<
The Shock sensor option activates the shock sensor functionality. If this option is
set to Yes, the zone operates according to the settings configured in "4.1.n.7
Gross and Pulse options" (see page 104).
Only the first eight inputs on the control panel and first eight on the input
expander support this option.
4.1.n.6.13 Extend EE
13 Extend EE
>No<
If the Extend EE option is Yes, the zone activation expands the entry time for the
value defined by "5.n.5 Prealarm time" on page 115.
Note:
After entry timer times out, local alarm activates.
4.1.n.6.14 Final door
14 Final door
>No<
When the Final door option is set to Yes, the zone has the exit terminator
functionality. If the zone is activated during the exit time, the exit timer is
terminated after the Final Set delay has expired (see "8.1.3.5 Final set delay" on
page 140) and the area is set.
4.1.n.6.15 Key latch
15 Key latch
>No<
If the Key latch option is set to Yes, the key switch zone input is latching. If the
zone state is active, the area is set. If the zone changes to normal, the area is
unset.