8.1.4.4 Input delay
4 Input delay
>
<
The Input delay value represents the delay between an input and appropriate
zone activation. The allowed range is 0 to 255 seconds.
8.1.4.5 Key box time
5 Key box time
>
<
The Key box time extends the exit time. Immediately after the exit timer expires,
the key box timer starts for duration of the defined time. Before this timer expires,
the zone must be closed. If it is not closed, a full alarm is triggered again even if
the previous trigger was also an alarm. During operation of the exit timer and key
box timer, openings and closings are not registered and do not cause an alarm.
The allowed range is 0 to 99 minutes.
8.1.4.6 Held open time
6 Held open time
>00:00'00<
The options define the time period of held open, after which the zone raises
"open too long" flag, which can be used for filter programming.
See "4.1.n.6.29 Held open" on page 103.
8.1.4.7 Inactive days
7 Inactive days
>
<
If a zone is inactive for longer than a time programmed in this menu (in days), an
appropriate inactive days event is activated for zone.
Allowed range is 0 to 127, 0 disables the timer for the zone.
Zone inactive day timers can be viewed and reset using "1.2.1.6 Inactive days"
menu described on page 48.

Engineer options

8.2 Engineer options
1>User Code Req
Yes
The Engineer options are options that apply to maintenance and installation
functions.
142
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual