 Simplified Setup Using the Setup Group
In the Setup Group, the drive lists the basic parameters needed to set up the drive for the application. It provides a
simplified way to get the application running right away by showing only the most important parameters.
Using the Setup Group
Figure 4.7
illustrates how to enter and how to change parameters in the Setup Group.
The first display shown when entering the Setup Group is the Application Selection menu. Skipping this display will
keep the current Setup Group parameter selection. The default setting for the Setup Group is a group of parameters most
commonly use in general-purpose applications. Pressing the ENTER key from the Application Selection display and
selecting an Application Preset will change the Setup Group to parameters optimal for the application selected.
Application Selection on page 114
In this example, the Setup Group is accessed to change b1-01 from 1 to 0. This changes the source of the frequency
reference from the control circuit terminals to the digital operator.
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.00A
LREF
JOG
FWD/REV
FWD
Frequency reference
appears when
powered up
<1> Use the up and down arrow keys to scroll through the Setup Group. Press the ENTER key to view or change parameter settings.
<2> To return to the previous menu without saving changes, press the ESC key.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
and
Setup Group Parameters on page 108
- MODE -
PRG
Quick Setting
HELP
FWD
DATA
<1>
- SETUP -
PRG
Application Sel
∗0∗
A1-06= 0
General
Home
FWD
DATA
Parameter Display
- SETUP -
PRG
Control Method
A1-02= 2
∗2∗
Open Loop Vector
Home
FWD
DATA
- SETUP -
PRG
Ref Source 1
∗1∗
b1-01= 1
Analog Input
Home
FWD
DATA
- SETUP -
PRG
Run Source 1
b1-02= 1
∗1∗
Digital Inputs
Home
FWD
DATA
- SETUP -
PRG
StallP Decel Sel
∗1∗
L3-04= 1
General Purpose
Home
FWD
DATA
Figure 4.7 Setup Group Example
4.3 The Drive and Programming Modes
for details.
Rdy
Rdy
Rdy
Entry Accepted
Rdy
Rdy
- SETUP -
PRG
Rdy
Ref Source 1
b1-01=
1
∗1∗
Analog Input
"1"
FWD
Control Circuit
Terminal
<2>
- SETUP -
PRG
Rdy
Ref Source 1
b1-01=
0
∗1∗
Operator
"1"
FWD
Operator
<2>
Refer to
4
107