H: Terminal Functions

H parameters are used to assign functions to the external terminals.
 H1: Multi-Function Digital Inputs
H1-01 to H1-08: Functions for Terminals S1 to S8
These parameters assign functions to the multi-function digital inputs. The various functions and their settings are listed
below in
Table
5.35.
No.
Parameter Name
H1-01
Multi-Function Digital Input Terminal S1 Function Selection
H1-02
Multi-Function Digital Input Terminal S2 Function Selection
H1-03
Multi-Function Digital Input Terminal S3 Function Selection
H1-04
Multi-Function Digital Input Terminal S4 Function Selection
H1-05
Multi-Function Digital Input Terminal S5 Function Selection
H1-06
Multi-Function Digital Input Terminal S6 Function Selection
H1-07
Multi-Function Digital Input Terminal S7 Function Selection
H1-08
Multi-Function Digital Input Terminal S8 Function Selection
<1> Number appearing in parenthesis is the default value after performing a 3-Wire initialization (A1-03 = 3330).
Setting
0
3-wire sequence
1
Local/remote selection
2
External reference 1/2 selection
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog reference selection
7
Accel/decel time selection 1
8
Baseblock command (N.O.)
9
Baseblock Command (N.C.)
A
Accel/decel ramp hold
B
Drive overheat alarm (OH2)
C
Analog terminal input selection
D
PG encoder disable
E
ASR integral reset
F
Through mode
10
Up command
11
Down command
12
Forward jog
13
Reverse jog
14
Fault reset
15
Fast Stop (N.O.)
16
Motor 2 selection
17
Fast Stop (N.C.)
18
Timer function input
19
PID disable
1A
Accel/decel time selection 2
1B
Program lockout
1E
Reference sample hold
20 to 2F
External fault
30
PID integral reset
31
PID integral hold
32
Multi-step speed reference 4
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Table 5.35 Multi-Function Digital Input Terminal Settings
Function
Setting
Range
1 to 9F
40 (F)
: Forward Run Command (2-wire sequence)
<1>
1 to 9F
41 (F)
: Reverse Run Command (2-wire sequence)
<1>
0 to 9F
24: External Fault (N.O., always detected, coast to stop)
0 to 9F
14: Fault Reset
0 to 9F
3 (0)
: Multi-Step Speed Reference 1
<1>
0 to 9F
4 (3)
: Multi-Step Speed Reference 2
<1>
0 to 9F
6 (4)
: Jog Reference Selection
<1>
0 to 9F
8: External Baseblock Command
Page
Setting
236
34
PID soft starter cancel
236
35
PID input level selection
237
40
Forward run command (2-wire sequence)
41
Reverse run command (2-wire sequence)
237
42
Run command (2-wire sequence 2)
43
FWD/REV command (2-wire sequence 2)
237
44
Offset frequency 1
237
45
Offset frequency 2
46
Offset frequency 3
237
47
Node setup
237
60
DC Injection Braking command
238
61
External Speed Search command 1
238
62
External Speed Search command 2
238
63
Field Weakening
238
65
KEB Ride-Thru 1 (N.C.)
238
66
KEB Ride-Thru 1 (N.O.)
67
Communications test mode
238
68
High Slip Braking
6A
Drive enabled
239
71
Speed/Torque Control switch
239
72
Zero Servo
239
75
Up 2 command
240
76
Down 2 command
239
77
ASR gain switch
240
78
External torque reference polarity inversion
240
7A
KEB Ride-Thru 2 (N.C.)
241
7B
KEB Ride-Thru 2 (N.O.)
241
7C
Short Circuit Braking (N.O.)
241
7D
Short Circuit Braking (N.C.)
241
7E
Forward/reverse detection
242
7F
Bi-directional PID output enable
242
90 to 97
DriveWorksEZ Digital input 1 to 8
242
9F
DriveWorksEZ disabled
5.7 H: Terminal Functions
Default
Function
Page
242
242
242
242
242
242
243
243
243
243
243
243
243
243
244
244
244
5
244
244
245
245
245
245
245
245
235