YASKAWA A1000 Technical Manual page 566

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

C.9 MEMOBUS/Modbus Data Table
Register No.
CPF Contents 3
bit 0
bit 1
bit 2
bit 3
bit 4 to 7
00D2H
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E, F
00D3H to 00D7H
Reserved
oFA0 Contents (CN5-A)
bit 0
bit 1
00D8H
bit 2 to 4
bit 5
bit 6
bit 7 to F
oFA1 Contents (CN5-A)
bit 0
bit 1
bit 2
bit 3
00D9H
bit 4
bit 5
bit 6
bit 7
bit 8 to F
00DAH to 00DBH
Reserved
oFA3 Contents (CN5-A)
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
00DBH
bit 7
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E, F
oFb0 Contents (CN5-B)
bit 0
bit 1
bit 2
00DCH
bit 3, 4
bit 5
bit 6
bit 7 to F
oFb1 Contents (CN5-B)
bit 0
bit 1
bit 2
bit 3
00DDH
bit 4
bit 5
bit 6
bit 7
bit 8 to F
00DEH to 00DFH
Reserved
566
Contents
ASIC Start-up Error (CPF32)
Watch-dog Error (CPF33)
ASIC Power/Clock Error (CPF34)
External A/D Converter Error (CPF35)
Reserved
Control Circuit Error (CPF40)
Control Circuit Error (CPF41)
Control Circuit Error (CPF42)
Control Circuit Error (CPF43)
Control Circuit Error (CPF44)
Control Circuit Error (CPF45)
Reserved
Option Compatibility Error (oFA00)
Option not properly connected (oFA01)
Reserved
A/D Conversion Error (oFA05)
Option Response Error (oFA06)
Reserved
Option RAM Fault (oFA10)
Option Operation Mode Fault (SLMOD) (oFA11)
Drive Receive CRC Error (oFA12)
Drive Receive Frame Error (oFA13)
Drive Receive Abort Error (oFA14)
Option Receive CRC Error (oFA15)
Option Receive Frame Error (oFA16)
Option Receive Abort Error (oFA17)
Reserved
Comm. ID Error (oFA30)
Model Code Error (oFA31)
Sumcheck Error (oFA32)
Comm. option timeout waiting for response (oFA33)
MEMOBUS Timeout (oFA34)
Drive timeout waiting for response (oFA35)
CI Check Error (oFA36)
Drive timeout waiting for response (oFA37)
Control Command Selection Error (oFA38)
Drive timeout waiting for response (oFA39)
Control Response Selection 1 Error (oFA40)
Drive timeout waiting for response (oFA41)
Control Response Selection 2 Error (oFA42)
Drive timeout waiting for response (oFA43)
Reserved
Option compatibility error (oFb00)
Option not properly connected (oFb01)
Same type of option card already connected (oFb02)
Reserved
A/D Conversion Fault (oFb05)
Option Response Error (oFb06)
Reserved
Option RAM Fault (oFb10)
Option Operation Mode Fault (SLMOD) (oFb11)
Drive Receive CRC Error (oFb12)
Drive Receive Frame Error (oFb13)
Drive Receive Abort Error (oFb14)
Option Receive CRC Error (oFb15)
Option Receive Frame Error (oFb16)
Option Receive Abort Error (oFb17)
Reserved
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual

Hide quick links:

Advertisement

Table of Contents
loading