B.3 Parameter Table
No.(Addr.)
Name
F7-73
PZD4 Read
(78DH)
F7-74
PZD5 Read
(78EH)
F7-75
PZD6 Read
(78FH)
F7-76
PZD7 Read
(790H)
F7-77
PZD8 Read
(791H)
F7-78
PZD9 Read
(792H)
F7-79
PZD10 Read
(793H)
<44> Cycle power for setting changes to take effect.
<45> If F7-13 is set to 0, then all IP Addresses (as defined with parameters F7-01 to F7-04) must be unique.
<46> Set F7-01 to F7-12 when F7-13 is set to 0.
<47> Set F7-15 when F7-14 is set to 0 or 2.
 H: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
H1: Multi-Function Digital Inputs
No.(Addr.)
Name
H1-01
Multi-Function Digital Input
(438H)
Terminal S1 Function Selection
H1-02
Multi-Function Digital Input
(439H)
Terminal S2 Function Selection
H1-03
Multi-Function Digital Input
(400H)
Terminal S3 Function Selection
H1-04
Multi-Function Digital Input
(401H)
Terminal S4 Function Selection
H1-05
Multi-Function Digital Input
(402H)
Terminal S5 Function Selection
H1-06
Multi-Function Digital Input
(403H)
Terminal S6 Function Selection
H1-07
Multi-Function Digital Input
(404H)
Terminal S7 Function Selection
H1-08
Multi-Function Digital Input
(405H)
Terminal S8 Function Selection
<31> Value in parenthesis is the default setting when a 3-wire initialization is performed (A1-03 = 3330).
482
All Modes
Sets MEMOBUS/Modbus address for PZD4 Read (PPO Read).
Values 0 disable the PZD4 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD5 Read (PPO Read).
Values 0 disable the PZD5 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD6 Read (PPO Read).
Values 0 disable the PZD6 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD7 Read (PPO Read).
Values 0 disable the PZD7 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD8 Read (PPO Read).
Values 0 disable the PZD8 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD9 Read (PPO Read).
Values 0 disable the PZD9 Read.
All Modes
Sets MEMOBUS/Modbus address for PZD10 Read (PPO Read).
Values 0 disable the PZD10 Read.
All Modes
Assigns a function to the multi-function digital inputs.
Refer to
H1 Multi-Function Digital Input Selections on page 483
values.
Note: Unused terminals should be set to F.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
Description
for a description of setting
Setting
Page
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Default: 0
Min: 0
Max: FFFF
Setting
Page
Default: 40 (F)
<31>
Min: 1
235
Max: 9F
Default: 41 (F)
<31>
Min: 1
235
Max: 9F
Default: 24
Min: 0
235
Max: 9F
Default: 14
Min: 0
235
Max: 9F
Default: 3 (0)
<31>
Min: 0
235
Max: 9F
Default: 4 (3)
<31>
Min: 0
235
Max: 9F
Default: 6 (4)
<31>
Min: 0
235
Max: 9F
Default: 8
Min: 0
235
Max: 9F