YASKAWA A1000 Technical Manual page 337

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

Digital Operator Display
CPF00 or CPF01
or
<1>
Cause
There is a self diagnostic error in control circuit.
Connector on the operator is damaged.
Digital Operator Display
Cause
Control circuit is damaged.
Digital Operator Display
Cause
There is a connection error.
Drive fails to operate properly due to electrical signal
interference.
Digital Operator Display
Cause
There is an error in EEPROM control circuit.
The power supply was switched off when parameters
were being saved to the drive.
Digital Operator Display
Cause
There is a fault connection between the terminal board
and control board.
Digital Operator Display
Cause
Hardware is damaged.
Digital Operator Display
Cause
Hardware is damaged.
Digital Operator Display
Cause
Hardware is damaged.
Digital Operator Display
Cause
Hardware is damaged.
Digital Operator Display
Cause
Hardware is damaged.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Control Circuit Error
<1>
• Cycle power to the drive.
• If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board,
contact YASKAWA or your nearest sales representative.
Replace the operator.
A/D Conversion Error
CPF02
An A/D conversion error or control circuit error occurred.
• Cycle power to the drive.
• If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board,
contact YASKAWA or your nearest sales representative.
Control Board Connection Error
CPF03
Connection error between the control board and the drive
• Turn the power off and check the connection between the control board and the drive.
• If the problem continues, replace either the control board or the entire drive.
• Check the various options available to minimize the effects of noise.
• Take steps to counteract noise in the control circuit, main circuit, and ground wiring.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or on the drive input power side.
• Ensure that other equipment such as switches or relays do not cause noise and use surge suppressors if required.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power supply input.
EEPROM Memory Data Error
CPF06
There is an error in the data saved to EEPROM.
• Turn the power off and check the connection between the control board and the drive.
• If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board,
contact YASKAWA or your nearest sales representative.
Reinitialize the drive (A1-03 = 2220, 3330).
CPF07
Terminal Board Connection Error
CPF08
• Turn the power off and reconnect the terminal board.
• If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board,
contact YASKAWA or your nearest sales representative.
CPF11
RAM Fault
Replace the drive.
FLASH Memory Fault
CPF12
Problem with the ROM (FLASH memory).
Replace the drive.
Watchdog Circuit Exception
CPF13
Self-diagnostics problem.
Replace the drive.
Control Circuit Fault
CPF14
CPU error (CPU operates incorrectly due to noise, etc.)
Replace the drive.
Clock Fault
CPF16
Standard clock error.
Replace the drive.
6.4 Fault Detection
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
6
337

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents