YASKAWA A1000 Technical Manual page 30

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

1.2 General Description
 Control Mode Selection
Table 1.2
gives an overview of the A1000 control modes and their various features.
Motor Type
Control Mode
Parameter Setting
Basic Description
Motor Type
Multi Motor
Motor data
unknown
High Speed
Accuracy
Type of
High Speed
Applications
Response
Zero Speed
Control
Torque Control
Operation
Torque Limit
Operation
PG Option Card
Speed Control
Range
Speed Accuracy
Control
Characteristics
Speed Response
Starting Torque 150% at 3 Hz 150% at 3 Hz
30
Table 1.2 Control Modes and their Features
Induction Motors
V/f
V/f w/PG
OLV
A1-02 = 0
A1-02 = 1
A1-02 = 2
V/f control
using motor
Open Loop
V/f control
speed
Vector control
feedback
IM
IM
IM
YES
N/A
N/A
YES
N/A
N/A
N/A
YES
YES
N/A
N/A
YES
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
YES
PG-B3 or
N/A
N/A
PG-X3
1:40
1:40
1:200
2 to 3%
0.03%
0.2%
3 Hz
3 Hz
10 Hz
(approx.)
(approx.)
200% at
0.3 Hz
Permanent Magnet Motors
CLV
OLV/PM
AOLV/PM
A1-02 = 3
A1-02 = 5
A1-02 = 6
Open Loop
Open Loop
Closed Loop
Vector control
Vector control
Vector control
for IPM
for PM motors
motors
IM
PM
IPM
N/A
N/A
N/A
N/A
N/A
N/A
YES
YES
YES
YES
N/A
YES
YES
N/A
YES
YES
N/A
YES
YES
N/A
N/A
PG-B3 or
N/A
N/A
PG-X3
1:20
1:1500
1:20
1:100
0.02%
0.2%
0.2%
50 Hz
10 Hz
10 Hz
100% at 5% 
200% at
100% at
speed
0 min
-1
5% speed
200% at
0 min
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Comments
CLV/PM
Default Setting is Open Loop Vector
A1-02 = 7
Control.
Closed Loop
Vector control
for PM motors
PM
N/A
N/A
YES
YES
YES
YES
YES
PG-X3
May fluctuate with characteristics and
motor temperature.
1:1500
Enabled for 1:100 when n8-57 = 1 (high
frequency injection enabled).
Induction Motor: Speed deviation rate
between speed reference value and motor
speed (100% = rated speed, motor
temperature 25C10C) when operating
0.02%
at normal status and when load is stable.
PM motor: Speed deviation when
operating at constant speed may fluctuate
with characteristics and motor temperature
(25C 10C).
Max. frequency of a speed reference signal
50 Hz
that the drive can follow. May fluctuate
with characteristics and motor temperature.
May fluctuate with characteristics and
motor temperature.
200% at
Performance may differ by capacity.
0 min
-1
200% at 0 min
-1
-1
(high frequency injection enabled).
enabled when n8-57 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents