YASKAWA A1000 Technical Manual page 512

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
U1-19
MEMOBUS/Modbus Error
(66H)
Code
U1-21
AI-A3 Terminal V1 Input
(77H)
Voltage Monitor
U1-22
AI-A3 Terminal V2 Input
(72AH)
Voltage Monitor
U1-23
AI-A3 Terminal V3 Input
(72BH)
Voltage Monitor
U1-24
Input Pulse Monitor
(7DH)
U1-25
Software Number (Flash)
(4DH)
U1-26
Software No. (ROM)
(5BH)
U1-29
Software No. (PWM)
(7AAH)
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<19> Display is in the following units.
 CIMR-A2A0004 to 2A0040, CIMR-A4A0002 to 4A0023: 0.01 A units
 CIMR-A2A0056 to 2A0312, CIMR-A4A0031 to 4A0675: 0.1 A units
 CIMR-A4A0930 to 4A1200: 1 A units
<22> The display resolution depends on the rated output power of the drive after the Drive Duty has been set in parameter C6-01. Drives with a
maximum output up to 11 kW will display this value in units of 0.01 kW (two decimal places). Drives with a maximum output greater than 11
kW will display this value in units of 0.1 kW (one decimal place).
<23> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are
checked using MEMOBUS/Modbus communications, the monitor value in MEMOBUS/Modbus communications is: displayed numeric value
/ 8192  drive' rated current (A), from the condition "8192 (maximum value) = drive' rated current (A)"
<60> In V/f and V/f w/PG control mode, 10 V = drive capacity (kW). In OLV, CLV, OLV/PM, AOLV/PM, or CLV/PM control mode, 10 V = motor
rated power (E2-11) (kW).
U2: Fault Trace
No. (Addr.)
Name
U2-01
Current Fault
(80H)
U2-02
Previous Fault
(81H)
U2-03
Frequency Reference at
(82H)
Previous Fault
U2-04
Output Frequency at Previous
(83H)
Fault
U2-05
Output Current at Previous
(84H)
Fault
U2-06
Motor Speed at Previous Fault
(85H)
U2-07
Output Voltage at Previous
(86H)
Fault
512
All Modes
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
0 0 0 0 0 0 0 0
All Modes
Displays the input voltage to terminal V1 on analog input card AI-A3.
All Modes
Displays the input voltage to terminal V2 on analog input card AI-A3.
All Modes
Displays the input voltage to terminal V3 on analog input card AI-A3.
All Modes
Displays the frequency to pulse train input terminal RP.
All Modes
FLASH ID
All Modes
ROM ID
All Modes
PWM ID
Note: This parameter is displayed in models CIMR-A4A0930 and 4A1200.
All Modes
Displays the current fault.
All Modes
Displays the previous fault.
All Modes
Displays the frequency reference at the previous fault.
All Modes
Displays the output frequency at the previous fault.
All Modes
Displays the output current at the previous fault.
Note: The unit is expressed in 1 A for models CIMR-A4A0930 and 4A1200.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Displays the motor speed at the previous fault.
All Modes
Displays the output voltage at the previous fault.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
1
Timed Out
0
Not Used
Refer to Model Number and Nameplate Check on page 32
Description
OLV
CLV
CLV/PM
Analog Output
Unit
Page
Level
No signal output
available
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
Determined by H6-02
1 Hz
No signal output
available
No signal output
available
No signal output
available
for details.
Analog Output
Unit
Page
Level
No signal output
available
No signal output
available
No signal output
0.01 Hz
available
No signal output
0.01 Hz
available
No signal output
<19> <23>
available
No signal output
0.01 Hz
available
No signal output
0.1 Vac
available

Hide quick links:

Advertisement

Table of Contents
loading