YASKAWA A1000 Technical Manual page 492

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

B.3 Parameter Table
H4: Multi-Function Analog Outputs
No.(Addr.)
Name
H4-01
Multi-Function Analog Output
(41DH)
Terminal FM Monitor Selection
H4-02
(41EH)
Multi-Function Analog Output
Terminal FM Gain
H4-03
(41FH)
Multi-Function Analog Output
Terminal FM Bias
H4-04
Multi-Function Analog Output
(420H)
Terminal AM Monitor Selection
H4-05
(421H)
Multi-Function Analog Output
Terminal AM Gain
H4-06
(422H)
Multi-Function Analog Output
Terminal AM Bias
Multi-Function Analog Output
H4-07
Terminal FM Signal Level
(423H)
Selection
Multi-Function Analog Output
H4-08
Terminal AM Signal Level
(424H)
Selection
H5: MEMOBUS/Modbus Serial Communication
Note: The settings for MEMOBUS/Modbus communications become effective when the drive is restarted.
No.(Addr.)
Name
H5-01
(425H)
Drive Node Address
<32>
H5-02
Communication Speed Selection
(426H)
H5-03
Communication Parity Selection
(427H)
H5-04
Stopping Method After
(428H)
Communication Error (CE)
H5-05
Communication Fault Detection
(429H)
Selection
H5-06
Drive Transmit Wait Time
(42AH)
H5-07
RTS Control Selection
(42BH)
492
All Modes
Selects the data to be output through multi-function analog output terminal FM.
Set the desired monitor parameter to the digits available in U-. For example, enter "103"
for U1-03.
All Modes
Sets the signal level at terminal FM that is equal to 100% of the selected monitor value.
All Modes
Sets the signal level at terminal FM that is equal to 0% of the selected monitor value.
All Modes
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U-. For example, enter "103"
for U1-03.
All Modes
Sets the signal level at terminal AM that is equal to 100% of the selected monitor value.
All Modes
Sets the signal level at terminal AM that is equal to 0% of the selected monitor value.
All Modes
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20 mA
All Modes
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20 mA
All Modes
Selects drive station node number (address) for MEMOBUS/Modbus terminals R+, R-, S+, S-.
Cycle power for the setting to take effect.
All Modes
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
7: 76800 bps
8: 115200 bps
Cycle power for the setting to take effect.
All Modes
0: No parity
1: Even parity
2: Odd parity
Cycle power for the setting to take effect.
All Modes
0: Ramp to stop
1: Coast to stop
2: Fast Stop
3: Alarm only
All Modes
0: Disabled
1: Enabled. If communication is lost for more than two seconds, a CE fault will occur.
All Modes
Set the wait time between receiving and sending data.
All Modes
0: Disabled. RTS is always on.
1: Enabled. RTS turns on only when sending.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
Description
Setting
Page
Default: 102
Min: 000
262
Max: 999
Default: 100.0%
Min: -999.9%
263
Max: 999.9%
Default: 0.0%
Min: -999.9%
263
Max: 999.9%
Default: 103
Min: 000
262
Max: 999
Default: 50.0%
Min: -999.9%
263
Max: 999.9%
Default: 0.0%
Min: -999.9%
263
Max: 999.9%
Default: 0
Min: 0
264
Max: 1
Default: 0
Min: 0
264
Max: 1
Setting
Page
Default: 1F
Min: 0
550
Max: FF
Default: 3
Min: 0
550
Max: 8
Default: 0
Min: 0
550
Max: 2
Default: 3
Min: 0
550
Max: 3
Default: 1
Min: 0
551
Max: 1
Default: 5 ms
Min: 5 ms
551
Max: 65 ms
Default: 1
Min: 0
551
Max: 1