7.4 Cooling Fan and Circulation Fan
3.
Remove the screws holding the fan unit in place and slide the fan unit out of the drive.
Figure 7.21
4.
Remove the fan guard and replace the cooling fans.
Note: Make sure the fan cable does not get pinched between parts when reassembling the fan unit.
Figure 7.22
2A0169, 2A0211, 2A0250, 2A0312,
4A0139, 4A0165, 4A0208
Cooling Fan Wiring: 2A0169, 2A0211, 4A0139, and 4A0165
1.
Position the protective tube so that the fan connector sits in the center of the protective tube.
392
Figure 7.21 Removing the Fan Unit: 2A0169 to 2A0415, 4A0139 to 4A0362
A
C
A – Fan Guard
B – Cable Cover
Figure 7.22 Fan Unit Disassembly: 2A0169 to 2A0415, 4A0139 to 4A0362
Protective tube
4A0250, 4A0296
A
B
C
C – Cooling Fan
D – Circulation Fan
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
2A0360, 2A0415,
4A0362
A
B
C