Q: Driveworksez Parameters - YASKAWA A1000 Technical Manual

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

No. (Addr.)
Name
o4-07
DC Bus Pre-Charge Relay
(523H)
Maintenance Setting
o4-09
IGBT Maintenance Setting
(525H)
o4-11
U2, U3 Initialization
(510H)
o4-12
kWh Monitor Initialization
(512H)
o4-13
Number of Run Commands
(528H)
Counter Initialization
 q: DriveWorksEZ Parameters
No. (Addr.)
Name
q1-01 to
q6-07
DriveWorksEZ Parameters
(1600H to
1746H)
 r: DriveWorksEZ Connection Parameters
No. (Addr.)
Name
r1-01 to
r1-40
DriveWorksEZ Connection
(1840H to
Parameters 1 to 20 (upper/lower)
1867H)
 T: Motor Tuning
Enter data into the following parameters to tune the motor and drive for optimal performance
T1: Induction Motor Auto-Tuning
No. (Addr.)
Name
T1-00
Motor 1/Motor 2 Selection
(700H)
T1-01
(701H)
Auto-Tuning Mode Selection
<37>
T1-02
Motor Rated Power
(702H)
T1-03
Motor Rated Voltage
(703H)
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
All Modes
Sets the point at which the cumulative timing for the soft charge bypass relay maintenance
starts. View monitor U4-06 to determine when the bypass relay may require replacement.
All Modes
Sets the point at which the cumulative timing for the IGBTs maintenance starts.
View monitor U4-07 to determine when the IGBTs may require replacement.
All Modes
0: U2- and U3- monitor data is not reset when the drive is initialized (A1-03).
1: U2- and U3- monitor data is reset when the drive is initialized (A1-03). (The value
of o4-11 is automatically returned to 0.)
All Modes
0: U4-10 and U4-11 monitor data is not reset when the drive is initialized (A1-03).
1: U4-10 and U4-11 monitor data is reset when the drive is initialized (A1-03). (The value of
o4-12 is automatically returned to 0.)
All Modes
0: U4-02 monitor data is not reset when the drive is initialized (A1-03).
1: U4-02 monitor data is reset when the drive is initialized (A1-03). (The value of o4-13 is
automatically returned to 0.)
All Modes
Reserved for DriveWorksEZ
All Modes
DriveWorksEZ Connection Parameters 1 to 20 (upper/lower)
V/f
V/f w/PG
OLV/PM
AOLV/PM
1: Motor 1 (sets E1-, E2-)
2: Motor 2 (sets E3-, E4-)
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line Resistance
3: Rotational Auto-Tuning for V/f Control (necessary for Energy Savings and Speed Estimation
Speed Search)
4: Stationary Auto-Tuning 2
5: Stationary Auto-Tuning 3
8: Inertia Tuning (perform Rotational Auto-Tuning prior to Inertia Tuning)
9: ASR Gain Tuning (perform Rotational Auto-Tuning prior to ASR Gain Auto-Tuning)
Note 1. Stationary Auto-Tuning 3 is not available in models CIMR-A4A0930 and 4A1200.
2. Inertia Tuning and ASR Gain Auto-Tuning might not be available if gears are between
the machine and the motor shaft.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated power as specified on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated voltage as specified on the motor nameplate.
Description
Description
Description
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default: 0%
Min: 0%
319
Max: 150%
Default: 0%
Min: 0%
319
Max: 150%
Default: 0
Min: 0
319
Max: 1
Default: 0
Min: 0
320
Max: 1
Default: 0
Min: 0
320
Max: 1
Setting
Page
Refer to Help in the
320
DWEZ software.
Setting
Page
Default: 0
Min: 0
320
Max: FFFF
Setting
Page
Default: 1
Min: 1
127
Max: 2
Default: 0
Min: 0
128
Max: 4, 5, 8, 9
<10>
Default:
<9>
Min: 0.00 kW
128
Max: 650.00 kW
Default: 200.0 V
<18>
Min: 0.0 V
128
Max: 255.0 V
<18>
507