B.3 Parameter Table
n3: High Slip Braking (HSB) and Overexcitation Braking
No. (Addr.)
Name
n3-01
High Slip Braking Deceleration
(588H)
Frequency Width
n3-02
High Slip Braking Current Limit
(589H)
n3-03
High Slip Braking Dwell Time at
(58AH)
Stop
n3-04
High-Slip Braking Overload Time
(58BH)
n3-13
Overexcitation Deceleration Gain
(531H)
n3-14
High Frequency Injection during
(532H)
Overexcitation Deceleration
n3-21
High-Slip Suppression Current
(579H)
Level
n3-23
Overexcitation Operation
(57BH)
Selection
<50> The default setting is determined by the values set to duty selection (C6-01) and the carrier frequency reduction selection (L8-38).
n5: Feed Forward Control
No. (Addr.)
Name
n5-01
Feed Forward Control Selection
(5B0H)
n5-02
Motor Acceleration Time
(5B1H)
n5-03
Feed Forward Control Gain
(5B2H)
<9> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
<14> Default setting value is dependent on the motor code set to E5-01.
502
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the output frequency reduction step width for when the drive stops the motor using HSB.
Set as a percentage of the maximum output frequency. Increase this setting if overvoltage
occurs during HSB.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the current limit during HSB as a percentage of the motor rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time the drive will run with minimum frequency (E1-09) at the end of deceleration.
If this time is set too low, the machine inertia can cause the motor to rotate slightly after HSB.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time required for an HSB overload fault (oL7) to occur when the drive output
frequency does not change during an HSB stop. This parameter does not typically require
adjustment.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the gain applied to the V/f pattern during Overexcitation Deceleration (L3-04 = 4).
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets output current level at which the drive will start reducing the overexcitation gain in order to
prevent a too high motor slip during Overexcitation Deceleration. Set as a percentage of the
drive rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Enabled in both directions
1: Enabled only when rotating forward
2: Enabled only when in reverse
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time required to accelerate the motor at the rated torque from stop to rated speed.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the ratio between motor and load inertia. Lower this setting if overshoot occurs at the end
of acceleration.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Setting
Page
Default: 5%
Min: 1%
303
Max: 20%
Default:
<50>
Min: 100%
304
Max: 200%
Default: 1.0 s
Min: 0.0 s
304
Max: 10.0 s
Default: 40 s
Min: 30 s
304
Max: 1200 s
Default: 1.10
Min: 1.00
305
Max: 1.40
Default: 0
Min: 0
305
Max: 1
Default: 100%
Min: 0%
305
Max: 150%
Default: 0
Min: 0
305
Max: 2
Setting
Page
Default: 0
Min: 0
306
Max: 1
Default:
<9> <14>
Min: 0.001 s
306
Max: 10.000 s
Default: 1.00
Min: 0.00
307
Max: 100.00