Alarm And Error Displays - YASKAWA A1000 Technical Manual

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

 Alarm and Error Displays
Faults
Table 6.9
gives an overview of possible fault codes. As conditions such as overvoltage can trip both a fault and an alarm,
it is important to distinguish between faults and alarms in order to find the right corrective action.
When the drive detects a fault, the ALM indicator LEDs lights and the fault code appears on the display. The drive fault
contact MA-MB-MC will be triggered. If the ALM LED blinks and the code appearing on the operator screen is flashes,
then an alarm has been detected. See
Digital Operator Display
LED Operator
LCD Operator
boL
Braking Transistor Overload Fault
bUS
Option Communication Error
MEMOBUS/Modbus Communication
CE
Error
CF
Control Fault
CoF
Current Offset Fault
,
CPF00, CPF01
Control Circuit Error
<1>
CPF02
A/D Conversion Error
CPF03
Control Board Connection Error
CPF06
EEPROM Memory Data Error
<4>
,
CPF07,
Terminal Board Connection Error
CPF08
CPF11
RAM Fault
CPF12
FLASH Memory Fault
CPF13
Watchdog Circuit Exception
CPF14
Control Circuit Fault
CPF16
Clock Fault
CPF17
Timing Fault
CPF18
Control Circuit Fault
CPF19
Control Circuit Fault
,
CPF20, CPF21
Control Circuit Error
<1>
CPF22
Hybrid IC Error
CPF23
Control Board Connection Error
CPF24
Drive Unit Signal Fault
<4>
CPF25
Terminal Board not Connected
to
,
CPF26 to CPF35,
Control Circuit Error
CPF40 to CPF45
to
<2>
Speed Deviation (for Control Mode with
dEv
PG and PM Open Loop Vector Control
Mode without PG)
dv1
Z Pulse Fault
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Minor Faults and Alarms on page 333
Table 6.9 Fault Displays (1)
Name
Page
LED Operator
336
336
336
336
336
337
337
337
337
337
337
337
337
337
337
338
338
338
338
338
338
338
338
338
338
339
6.3 Drive Alarms, Faults, and Errors
for a list of alarm codes.
Digital Operator Display
LCD Operator
dv2
Z Pulse Noise Fault Detection
dv3
Inversion Detection
dv4
Inversion Prevention Detection
dv7
Polarity Judge Timeout
,
dWAL,
DriveWorksEZ Fault
dWFL
EEPROM Memory DriveWorksEZ Data
dWF1
Error
E5
MECHATROLINK Watchdog Timer Error
EF0
Option Card External Fault
to
EF1 to EF8
External Fault (input terminal S1 to S8)
Err
EEPROM Write Error
FAn
Internal Fan Fault
FbH
Excessive PID Feedback
FbL
PID Feedback Loss
GF
Ground Fault
LF
Output Phase Loss
LF2
Output Current Imbalance
LF3
Power Unit Output Phase Loss 3
<2>
LSo
LSo Fault
nSE
Node Setup Error
oC
Overcurrent
Option Card Connection Error at Option
oFA00
<4>
Port CN5-A
oFA01
Option Card Fault at Option Port CN5-A
to
Option Card Error Occurred at Option Port
oFA03 to oFA06
CN5-A
,
Option Card Error Occurred at Option Port
oFA10, oFA11
CN5-A
to
oFA12 to oFA17
Option Card Connection Error (CN5-A)
to
Comm. Option Card Connection Error
oFA30 to oFA43
(CN5-A)
oFb00
Option Card Fault at Option Port CN5-B
<4>
Name
Page
339
339
339
339
339
339
340
340
340
340
340
340
341
341
341
341
341
342
342
342
342
343
6
343
343
343
343
343
331

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents