4.3 The Drive and Programming Modes

◆ Simplified Setup Using the Setup Group

In the Setup Group, the drive lists the basic parameters needed to set up the drive for an elevator application. This group
expedites the startup process for an elevator application by showing only the most important parameters for the
application.
Using the Setup Group
Figure 4.7
illustrates how to enter and how to change parameters in the Setup Group.
The first display shown when entering the Setup Group is the Control Method menu. Skipping this display will keep the
current Setup Group parameter selection. The default setting for the Setup Group is a group of parameters most
commonly use in control methods.
In this example, the Setup Group is accessed to change b1-01 from 0 to 1. This changes the source of the speed reference
from the digital operator to the control circuit terminals.
- MODE -
DRV
Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00%
RSEQ
U1-03= 0.00A
LREF
FWD
FWD/REV
Speed reference
appears when
powered up
<1> Use the up and down arrow keys to scroll through the Setup Group. Press the ENTER key to view or change parameter settings.
<2> To return to the previous menu without saving changes, press the ESC key.
102
- MODE -
PRG
Quick Setting
HELP
FWD
DATA
- SETUP -
PRG
<1>
Control Method
A1-02= 2
∗2∗
Open Loop Vector
Home
FWD
- SETUP -
PRG
Speed Ref Sel
∗0∗
b1-01= 0
Operator
Home
FWD
- SETUP -
PRG
Up/Dn Command Sel
b1-02= 1
∗1∗
Digital Inputs
Home
FWD
- SETUP -
PRG
StallP Accel Sel
∗1∗
L3-01= 1
General Purpose
Home
FWD
Figure 4.7 Setup Group Example
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Rdy
DATA
Rdy
DATA
Entry Accepted
Rdy
DATA
Rdy
DATA
YEA_common
- SETUP -
PRG
Rdy
Speed Ref Sel
b1-01=
0
∗0∗
Operator
"1"
FWD
Control Circuit
Terminal
<2>
- SETUP -
PRG
Rdy
Speed Ref Sel
∗0∗
b1-01=
0
Analog Input
"1"
FWD
Operator
<2>