YASKAWA A1000 Technical Manual page 86

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

3.9 Control Circuit Wiring
NOTICE: Use shielded twisted-pair cables as indicated to prevent operating faults. Improper wiring practices could result in drive or
equipment malfunction due to electrical interference.
Connect control wires as shown in
Figure 3.27
To disconnect control wires from the terminals use the procedure described in
enters the terminal with a pair of pliers, then use a straight-edge screw driver to release the terminal and pull the wire out.
If it fits tightly, e.g. if ferrules are used, turn the wire for about 45 and then pull it gently out. Use this procedure to
remove the wire jumper between terminals HC, H1 and H2 that is preinstalled at shipping.
Figure 3.28
When setting the frequency by analog reference from an external potentiometer, use shielded twisted-pair wires (treating
wire ends as shown in
Figure 3.26
Figure 3.29
NOTICE: The analog signal wiring between the drive and the operator station or peripheral equipment should not exceed 50 meters
when using an analog signal from a remote source to supply the frequency reference. Failure to comply could result in poor system
performance.
86
Figure 3.24
and
Figure
Control Wires
Terminal Board
Figure 3.24 Terminal Board Wiring Guide
Push down to open
the terminal
Control Wires
Terminal Board
Figure 3.25 Removing Wires from the Terminal Board
and connect the shield to the ground terminal (E [G]) of the drive.
A
A – Drive side
B – Insulation
C – Control device side
Figure 3.26 Preparing the Ends of Shielded Cables
3.25.
Push wire end
into terminal
Turn the wire ~ 45
and pull it out of the
terminal.
Use a screwdriver with a blade
width of max 2.5 mm and a
thickness of max 0.4 mm
E
B
C
D
D –Shield sheath (insulate with tape)
E –Shield
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Figure
3.25. Grasp the wire where it